The SunWize TM ground mounted 1500 Wp PV Hybrid Power Station

1. Photovoltaic (“PV”) Panels Siemens Solar high-efficiency, single crystal silicon PV modules provide higher amp-hour per watt output than other technologies and include dual bypass diode protection. Modular PV panels permit expansion to accommodate increased loads.

2. Adjustable Array Structure PV array tilt is easily adjustable from 30-60 degrees to maximize solar energy. Further adjustment of 0-30 degrees possible with special positioning bars.

3. Control Center The control enclosure is a NEMA 4 powder coated steel box housing the power distribution components (DC Controller/distribution, Inverter and AC distribution), disconnects, system monitor and appropriate wire terminals. Enclosure is provided with rainproof vents and a ground fault protected electrical outlet. Optional remote monitoring equipment is available.

4. Inverter/Battery Charger Trace microprocessor-controlled high-efficiency, sine wave inverter with three stage temperature compensated battery charger. Peak conversion efficiency of 96%, protection circuitry, LCD display with user and setup menus.

5. DC Controller Solid state, low frequency, pulse-width modulated solar charge control with battery temperature compensation and automatic night time disconnect. Customer DC interface conforms to U.S. National Electric Code and provides easy access and flexibility for multiple DC load requirements.

6. AC Distribution Panel Customer AC breaker panel conforms to U.S. National Electric Code, provides surge protection and flexibility for multiple AC load requirements.

7. DC Combiner Box Provides PV circuit disconnects and lightning/surge protection for electronic equipment.

8. Ventilator Fan Designed for active ventilation of hybrid battery enclosure to prevent accumulation of hydrogen gas.

9. Batteries Available in three battery types: economy flooded lead acid, industrial flooded lead acid and sealed lead acid. Flooded lead acid battery comes with recombiner caps to minimize water loss. Sealed battery available for maintenance-free performance. The control system maintains the batteries between 20% and 100% state of charge.

10. Battery Enclosure Insulated, vented thermoplastic unit with lockable lid and drain plug. Designed to minimize battery temperature extremes, eliminate battery bank hot spots, prevent freezing and extend useful battery life. Industrial battery cells are secured within a grid and surrounded by a water jacket.

11. Generator (Hybrid only) Industrial air-cooled, propane generator results in reduced maintenance requirements. Includes battery, alternator, remote start/stop contacts, self-contained protection and automatic safety shutdowns. Package includes weatherproof housing, vibration isolators on steel skid, flexible couplings, and replaceable dry element air filter. Available in three sizes. Other fuel types available.

12. Structure Industrial grade, heavy-gauge steel coated with a durable polyurethane or optional galvanized finish. Available in four configurations: ground mount, road trailer, off-road trailer and breakdown kit.

 
 

Hybrid and Stand-Alone Configurations

SunWize™ Power Stations are available in two configurations: “hybrid” power stations that have a generator and “stand-alone” power stations, without a generator. The SunWize™ Hybrid Power Station uses a propane or diesel powered electric generator to supplement battery charging. The SunWize™ Stand-Alone Power Station is powered exclusively by the PV modules.

Several factors must be considered when choosing between a hybrid or stand-alone configuration. Hybrid stations are sized to provide 25-75 percent of the load requirements by the engine generator, resulting in a lower first-cost for a given load. Stand-alone PV systems are sized to provide 100 percent of the load during the worst case solar conditions, and offer very low operating and maintenance costs. While the hybrid units do require fuel supply and engine maintenance, engine run time and operating costs are greatly reduced relative to diesel engine installations. Refer to the chart below for more detailed comparative information.

  PV Stand Alone PV Hybrid w/Gen Diesel Utility Extension
Fuel Costs None Moderate High None
Reliability Excellent Depends on Maintenance Depends on Maintenance High
Relative Capital Costs High Moderate Low Depends on Distance
Relative Operating Costs Low Moderate High Low
Maintenance Low Moderate High Low
Fuel Dependence None Low High Moderate
Pollution None Low High Moderate
 
 
Power Station Physical Specifications
Physical specifications diagram

Note: 1800 Wp Array shown in 30é position; height at maximum angle of 60é is 151'.

Total system shipping weight is 3200 ± 200 lbs. (1450 ± 90 kg).

Structure (option "S")

Order#
Ground Mount, two-piece S01*
Ground Mount, breakdown kit S02
Heavy-duty Road-rated Trailer, dual-axle S03
 
Monitoring** (option "M")

Order#
Local Monitoring M01*
Remote Monitoring/Control Panel, 50ft. (15m) cable M02
Remote Monitoring/Control adapter & PC software M03
 
System Type
Array Stand-Alone Price Hybrid
(w/Gen.)
Price
Wp Order#   Order#  
900
PS-900 $23,032 PSG-900 $30,400
1200 PS-1200 $25,228 PSG-1200 $33,725
1500 PS-1500 $27,544 PSG-1500 $35,625
1800 PS-1800 $29,919 PSG-1800 $37,995
2400 PS-2400 $31,819 PSG-2400 $39,895
 
Peak Inverter Power / System Voltage
(option "T")

Order#
4.0 kVA, 24VDC: 120VAC, 60Hz, 1¸, 2-wire T4024*
3.0 kVA, 24VDC: 230VAC, 50Hz, 1¸, 2-wire T3024E
4.0 kVA, 24VDC: 220VAC, 60Hz, 1¸, 2-wire T4024W
5.5 kVA, 48VDC: 120VAC, 60Hz, 1¸, 2-wire T5548
4.5 kVA, 48VDC: 230VAC, 50Hz, 1¸, 2-wire T4548E
8.0 kVA, 24VDC: 120/240VAC, 60Hz, 1¸,
3-wire
T8024D
 
Battery (option "B")

Order#
Industrial lead acid, flooded 2V cells, 1000Ah B01*
Economy lead acid, flooded 6V cells, 700Ah B02
Valve-regulated lead acid, sealed 12V cells, 840Ah B05
 
Generator (option "G")

Order#
6 kVA air-cooled, 2-cyl., LP (propane) fuel G01*
10 kVA air-cooled, 4-cyl., LP (propane) fuel G04
7.5 kVA air cooled, 2-cyl., diesel fuel G05
 

* Denotes standard configuration equipment.

** Monitoring includes: array current, battery voltage, genset voltage, genset current, genset run hours, load voltage, load current, load frequency, diagnostic messages.

Solar performance world map

HYBRID POWER STATION SIZING AND PERFORMANCE

“Sizing” a PV power system means determining how much energy is required (i.e., the system "load") and how many solar modules are required to generate it. For hybrid power stations, the load is served by a combination of the PV array and the engine generator. The chart below provides an estimate of the PV array size (in peak watts) required to generate 50% of the daily AC load. Use the accompanying map to select the color zone that corresponds to your specific location.

SOLAR INSOLATION

This map divides the world into five solar performance regions based on a yearly average of daily hours of sunlight for an array at latitude tilt. Specific sites within each region will differ as local weather conditions and seasonal changes can significantly affect the amount of sunlight available. The annual insolation received by the array can be increased by 5-10% by using the adjustable tilt feature of the Power Station twice per year (in March and October).

Array Size (Watts) for Hybrid AC Power Station
Daily AC Load LOCATION
A B C D E
4.0-6.0 1200 1200 900 900  
6.0-8.0 1800 1500 1200 1200 900
8.0-10.0 2400 1800 1500 1500 1200
10.0-12.0   2400 1800 1800 1500
12.0-14.0   2400 2400 2400 1800
14.0-16.0     2400 2400 2400
16.0-18.0         2400
           
 

 

       
  questions button  

To purchase products with your credit card call 800.799.1122

To pay by check or money order send to:
North Coast Power • Box 151 • Cazadero, CA • 95421

For live help to size and price your system call 800.799.1122
For an email quote
on the correct system for you
click here.

       
 
top of page | home | solar | wind | hydro | site map | contact us